At a glance
- The health floor
- 18°C in rooms you use — UKHSA and NHS guidance, and the point below which the body shows adverse effects
- UK price cap, October to December 2026
- 26.32p per kWh of electricity (VAT removed until 31 March 2027), 7.97p per kWh of gas
- A kWh of heat
- 8.86p from a 90% boiler, 8.77p from a heat pump at COP 3.0, 26.32p from a fan heater
- One degree
- +5.0% of the heating load at 0°C outside, +6.7% at 5°C, +10.0% at 10°C
- A 1.5 kW heater
- 39.5p an hour; eight hours a day for a month is £94.75
- Flow temperature 80°C → 60°C
- 12% less gas for heating, 17 minutes longer to warm up, 0.5°C cooler on average
Every winter question about heating reduces to two quantities that are rarely put side by side: how many kilowatt-hours of heat the house needs, and what a kilowatt-hour of heat costs from the system installed. Neither is a matter of opinion, and both can be worked out on the back of an envelope. This guide does the working, so the next decision — a degree, a timer, a boiler setting, an insulation quote — can be judged against a number rather than a slogan.
The 18°C line, and what going below it costs
Start with the constraint that outranks the arithmetic. UK health guidance — the UK Health Security Agency's Keeping warm and well guidance and the NHS — asks households to heat the rooms they spend time in, the living room and the bedroom, to at least 18°C if they can. The UKHSA's own summary of the evidence, published on 13 November 2026, is more specific than the slogan: outdoors, health effects begin at average temperatures of 4 to 8°C, and indoors, below 18°C is where the body begins to show adverse effects. Risk accumulates with the number of days spent at moderately cold temperatures, not only on the coldest days.
That reframes what "turning it down" means. The useful range for a thermostat is 18 to 21°C, and the savings question is about where inside that band a household sits, not about how far below it they can go. A bedroom at 16°C overnight is a different proposition from a living room at 16°C all day, which is why health advice separates rooms by how long people sit still in them.
What a kilowatt-hour of heat costs
The unit that matters is not the price of gas or electricity; it is the price of delivered heat. A condensing boiler turns about 90% of the gas it burns into heat in the radiators. An air-source heat pump moves three to four kilowatt-hours of heat for every one of electricity — the Energy Saving Trust's figure for a well-set-up system, and the number to use before a specific model's data sheet. A fan heater, an oil-filled radiator and an electric boiler all convert at 100%, which sounds good until the tariff is applied.
| System | Delivered heat per unit in | UK, p per kWh of heat | US, ¢ per kWh of heat | Korea, ₩ per kWh of heat |
|---|---|---|---|---|
| Condensing gas boiler | 90% | 8.86 | 9.9 | 99 |
| Heat pump, COP 3.0 | 300% | 8.77 | 6.05 | 86 |
| Heat pump, COP 2.5 in a cold snap | 250% | 10.53 | 7.26 | 103 |
| Old non-condensing boiler | 70% | 11.39 | 12.7 | 127 |
| Fan heater, panel heater, electric boiler | 100% | 26.32 | 18.2 | 258 |
The inputs: the UK price cap for 1 October to 31 December 2026 sets electricity at 26.32p per kWh and gas at 7.97p, averaged across England, Scotland and Wales for direct-debit customers, and the government has removed VAT from electricity for the six months to 31 March 2027 while gas keeps 5%. That makes electricity 3.3 times the price of gas per unit. Divide 26.32 by 7.97 and the heat pump-versus-boiler argument falls out: at COP 3.0 the heat pump costs 8.77p per kWh of heat against the boiler's 8.86p — a dead heat, decided by a tenth of a penny, on a tariff where the ratio is 3.3 rather than the 4 or 5 that heat pump economics usually assumes. In the United States the same comparison leans the other way: residential electricity averaged 18.16¢ per kWh in August 2026 while residential gas averaged $27.05 per thousand cubic feet, which is about 8.9¢ per kWh of gas and 9.9¢ per kilowatt-hour of heat at 90%, so a heat pump at COP 3 lands at 6.05¢ and wins by a third.
One figure in that paragraph has a date on it. Ofgem announces the cap for 1 January to 31 March 2027 by 25 November 2026, and Cornwall Insight's final forecast on 18 November put electricity at 32.54p and gas at 10.90p — a 26 per cent rise in the typical annual bill, to £2,166. If that is confirmed, every number here moves: the boiler goes to 12.11p per kWh of heat and the COP-3 heat pump to 10.85p, so the dead heat becomes a 10 per cent win for the heat pump, because gas rises faster than electricity in the forecast and the ratio falls from 3.3 to 3.0. The arithmetic in this guide is stable; the tariff under it is not, which is why the numbers are dated.
Korea is the awkward case, and the most instructive. Seoul city gas for residential use is 22.5268 won per megajoule before 10% VAT — 89 won per kWh of gas, and 99 won per kWh of heat through a 90% boiler. Korean residential electricity is progressive: 120.0 won per kWh up to 200 kWh, 214.6 won from 201 to 400, and 307.3 won above 400, plus a climate charge of 9.0 and a fuel-adjustment charge of 5.0, then 10% VAT and the 2.7% industry levy. That makes the second tier about 258 won per kWh and the third about 363. A heat pump on the second tier costs 86 won per kWh of heat and beats gas; on the third tier it costs 121 won and loses. The efficient machine is only efficient at the tariff it actually runs on — which is why a heat pump makes sense with a full flat and a small electricity bill, and why the same heat pump in a household already over 400 kWh a month should be judged at 121 won, not 86.
Why one degree is worth 5 to 20 per cent
Heat loss is proportional to the difference between indoor and outdoor temperature. Set the thermostat one degree higher and that difference grows by one kelvin, which is a bigger share of a small difference than of a large one. This is the whole explanation for the disagreement between the "about 10% a degree" rule and the experience of people whose bills barely moved in January.
| Outdoor temperature | Indoor-to-outdoor difference at 20°C | Extra heat demand at 21°C | Extra demand at 18°C instead of 20°C |
|---|---|---|---|
| 0°C | 20 K | +5.0% | −10.0% |
| 5°C | 15 K | +6.7% | −13.3% |
| 10°C | 10 K | +10.0% | −20.0% |
| 15°C | 5 K | +20.0% | −40.0% |
The rule of thumb is the 10°C case, and it is where almost all published figures come from: the Energy Saving Trust's own current advice is that turning a thermostat down from 22°C to 21°C saves around £120 a year in Great Britain, and its wider rule is roughly 10% of the heating bill per degree. Both are reasonable at average winter temperatures of around 10°C. In a cold snap the same degree is worth half as much, and in October, when it is 15°C outside, it is worth twice as much — which is why the first degree turned down in autumn pays best and the last one in a February frost pays least. The advice is not wrong; it is a single point on a curve, and the curve is the one above.
The same arithmetic sets the reaction to a cold forecast. Turning the thermostat up when it gets colder does not heat the house faster — the boiler runs until the set temperature is reached, and it takes longer when it is colder outside. It simply raises the target. The one thing that genuinely responds to outdoor temperature is flow temperature, which is the subject of the section after next.
Where the heat goes: watts per kelvin
Every house has a heat-loss coefficient, written as watts per kelvin: the power needed to hold it one degree above the outside air. It is the sum of two things — the fabric, from each element's area and U-value, and the air that leaks out and has to be warmed, which costs about 0.33 watt-hours per cubic metre per kelvin.
Take a 1930s semi-detached house: 100 m² of floor, 240 m³ of volume, 70 m² of exposed solid brick wall, 20 m² of single-glazed window, 50 m² of uninsulated roof and 50 m² of floor over a ventilated void, with half an air change an hour.
| Element | Area or volume | Before | W/K | After a retrofit | W/K |
|---|---|---|---|---|---|
| Walls, solid brick | 70 m² | U 1.7 | 119 | U 0.3 | 21 |
| Windows | 20 m² | U 4.8 | 96 | U 1.2 | 24 |
| Roof | 50 m² | U 2.3 | 115 | U 0.13 | 6.5 |
| Floor | 50 m² | U 0.7 | 35 | U 0.25 | 12.5 |
| Ventilation | 240 m³ | 0.5 AC/h | 40 | 0.35 AC/h | 28 |
| Thermal bridging | +10% | — | 40 | +10% | 9 |
| Total | 445 | 101 |
Two things follow. The first is the scale: 445 W/K at a 15 K difference between inside and out is 6.7 kW of continuous heat, which is why the boiler in a house like this is a 24 kW unit and still runs flat out on a cold morning. The second is where the money is. Adding 270 mm of loft insulation removes 108 W/K — the largest single item on the list — while the windows, which people replace first because they are visible, are worth 72 W/K and cost twenty times as much. Draught-proofing is the cheapest 12 W/K in the building, and the Energy Saving Trust puts the saving at around £55 a year in Great Britain plus £45 more if there is an open chimney to seal when it is not in use.
The month, priced
Multiply the heat-loss coefficient by the temperature difference and the hours: kWh = W/K × K × hours ÷ 1,000. A 720-hour month at a 10 K average difference (20°C inside, 10°C outside) is 10.8 kWh per W/K; at 15 K it is 16.2.
| House | Heat loss | Load at 10 K | Month at 10 K | Month at 15 K | Cost of the 15 K month |
|---|---|---|---|---|---|
| Before retrofit | 445 W/K | 4.45 kW | 3,204 kWh | 4,807 kWh | £426 · $475 · ₩476,000 |
| Loft and cavity done, old glazing | 199 W/K | 1.99 kW | 1,430 kWh | 2,146 kWh | £190 · $212 · ₩213,000 |
| After full retrofit | 101 W/K | 1.01 kW | 726 kWh | 1,090 kWh | £96 · $108 · ₩108,000 |
These are steady-state figures, and they overstate a real bill, deliberately. They assume the house is held at 20°C around the clock, no heat arrives from cooking, lighting, appliances or people, and the whole volume is heated. In practice a 100 m² home puts a few hundred kilowatt-hours a month into itself just by being lived in, which matters little in a leaky house and a great deal in a tight one: it is the reason a retrofit's measured saving is smaller than the arithmetic and the reason a well-insulated house can be heated to 20°C with the boiler at half output on all but the coldest days. What the numbers are good for is comparing houses and elements, and for knowing the order of magnitude before an installer quotes.
What an hour of heater costs
Electric heaters are the clearest case because there is no efficiency to argue about: a kilowatt is a kilowatt, and the meter charges for it at the full electricity rate. This is what the same hour costs at the tariffs above.
| Appliance | Draw | UK per hour | US per hour | Korea per hour |
|---|---|---|---|---|
| Fan heater, low | 1.0 kW | 26.3p | 18.2¢ | ₩258 |
| Fan heater, typical | 1.5 kW | 39.5p | 27.2¢ | ₩387 |
| Fan heater, high | 2.0 kW | 52.6p | 36.3¢ | ₩516 |
| Heat pump delivering 1.5 kW of heat | 0.5 kW | 13.2p | 9.1¢ | ₩129 |
| Electric blanket | 0.1 kW | 2.6p | 1.8¢ | ₩26 |
Eight hours a day of a 1.5 kW heater is 360 kWh a month: £94.75 in Britain, $65 in the United States, ₩92,950 in Korea on the second tier. That is the number to hold against "just heat the one room". Heating one room with a fan heater can still be the right answer — a 12 m² room loses perhaps 0.3 kW against a whole house's 1.5 to 6.7 kW — but only when the door is shut and the room is not also being heated by the central system. A fan heater in a room with the radiators running is the most expensive way to raise a temperature that has already been paid for.
Flow temperature: the 12% hiding in a dial
A gas boiler's efficiency depends on how cool the water returning to it is, because that is what decides whether the flue gas's latent heat condenses inside the boiler or escapes up the chimney. Lower the flow temperature and the whole circuit runs cooler, the return temperature drops, and the boiler spends more of its time condensing.
The best evidence on how much that is worth comes from Nesta's Money Saving Boiler Challenge and the tests behind it. Salford's Energy House — a two-bedroom terraced house with solid brick walls, suspended timber floors and single glazing inside an environmental chamber at 4.5°C — was run at flow temperatures from 80°C down to 50°C with nine hours of heating a day and a 21°C set point in the living room.
| Change | Gas saved, heating only | Whole gas bill | Comfort effect |
|---|---|---|---|
| 80°C → 70°C | 5% | 3.9% | Barely measurable |
| 80°C → 60°C | 12% | 9.1% | 17 minutes longer to warm up; 0.5°C cooler on average |
| 80°C → 55°C | 16% | 12.1% | Needs bigger radiators or more run time |
| 80°C → 50°C | 23% | 17.4% | Only with a heat-pump-grade radiator system |
For a household burning 12,000 kWh of gas a year, with 9,000 of it for heating, 12% is 1,080 kWh — £86 at the current cap, and rather less effort than any insulation job. Two rules bound it. On a combi boiler the radiator dial can go to about 60°C, or 50 to 55°C in mild weather, but a conventional boiler with a hot-water cylinder must not go below 65°C, because the cylinder has to be stored hot enough to stop legionella growing. And a lower flow temperature means radiators that are warm rather than hot, so a house may need its heating to start 15 to 30 minutes earlier; Nesta's modelling puts the cost of extending run time by half an hour at 3 to 4 percentage points of that saving, which still leaves the job worth doing.
Thermostats, setbacks, and the warm-up myth
The most-repeated objection to turning the heating off is that reheating costs more than leaving it on. It does not, and the reason is an identity rather than an experiment: heat lost = heat-loss coefficient × (indoor − outdoor) × hours. Every hour spent at a lower indoor temperature loses less heat. A boiler that is off is not "working harder later" to make up for it; it is replacing heat that was not lost in the first place.
The honest caveats are about comfort and efficiency rather than energy. A house with heavy masonry walls takes time to come back up, so a two-hour setback saves very little and is felt. Reheating from cold at full output runs a heat pump at its least efficient (highest flow temperature), and a condensing boiler may spend part of the reheat above its condensing range. Programmer, thermostat and thermostatic radiator valves together are worth about £100 a year in Great Britain according to the Energy Saving Trust, which puts the controls themselves well above the exotic stuff.
What to set, in practical terms: room thermostat at the lowest temperature that is comfortable, normally 18 to 21°C; the living room at the top of that band and bedrooms at the bottom; TRVs at 3 to 4 in rooms used most and 2 to 3 in bedrooms, which is what makes heating one room rather than the house a real option. Do not turn the thermostat up to warm the house faster, because it does not. Do turn the flow temperature down, because that does change how the boiler burns.
The order to spend money
The Energy Saving Trust's current annual savings, for a gas-heated home in Great Britain, are the best available yardstick for what each job returns.
| Work | Typical cost | Saving a year | Simple payback |
|---|---|---|---|
| Draught-proofing windows, doors, floors | £250 installed | £55 | 4–5 years |
| Loft insulation, 0 → 270 mm | £750 | £190 | 4 years |
| Programmer, thermostat, TRVs | varies | £100 | 1–2 years |
| Cavity wall insulation | £2,200 | £200 | 11 years |
| Suspended timber floor insulation | varies | £55 | long |
| Solid wall insulation, external | £12,000–15,000 | £280 | decades |
The order that falls out of it is: the free settings first, because they cost nothing and are reversible; then draughts and loft, which are the cheapest watts per kelvin; then controls; then walls, which are the expensive ones and the ones to do as part of other work. The Energy Saving Trust's research puts about a quarter of an uninsulated home's heat loss through the roof and a third through the walls, which is the physical reason the £750 loft job beats the £2,200 cavity job on payback even though the walls leak more.
A winter checklist, in numbers
Set the room thermostat to 18–21°C, and put a thermometer in the rooms you sit in rather than trusting the dial. Turn the flow temperature down — 60°C on a combi, no lower than 65°C with a cylinder — and expect the house to be 0.5°C cooler and slower to warm. Set TRVs by room: 3–4 where you sit, 2–3 in bedrooms. Use the timer rather than the thermostat for hours when nobody is home; heat when needed beats heat all day at every outdoor temperature. Draught-proof the obvious gaps but leave trickle vents, airbricks and extractor fans alone — a sealed house with a gas hob needs its ventilation. Measure the meters before and after a change, in the same weather, because the difference between 8.86p and 26.32p per kilowatt-hour of heat is the largest number in this guide and the only way to know which one a household is paying is to read the bill.
Sources and checks
- Heat rooms used regularly to at least 18°C; cold indoors below 18°C where the body begins to show adverse effects — UKHSA, Keeping warm and well (updated 28 April 2026) and UKHSA, how cold weather affects health (13 November 2026)
- UK price cap, 1 October to 31 December 2026: electricity 26.32p per kWh with no VAT until 31 March 2027, gas 7.97p per kWh, standing charges 54.83p and 29.68p a day — Ofgem, price cap unit rates and Ofgem, changes to the cap for October to December 2026
- Next cap, 1 January to 31 March 2027, to be announced by 25 November 2026; final forecast of electricity at 32.54p and gas at 10.90p, a typical annual bill of £2,166, up 26% — Cornwall Insight, final price cap forecast, 18 November 2026, a forecast rather than a confirmed rate and not used in the tables above
- US residential electricity 18.16¢ per kWh, August 2026 — EIA, Electric Power Monthly table 5.6.A
- US residential natural gas $27.05 per thousand cubic feet, August 2026 — EIA, natural gas prices, residential and EIA, Natural Gas Monthly table 3 (PDF)
- Korean residential electricity: 120.0, 214.6 and 307.3 won per kWh by tier, with climate and fuel-adjustment charges, VAT and the industry levy — Korean Ministry of Government Legislation, residential electricity charges and KEPCO, tariff tables
- Seoul residential gas 22.5268 won per MJ from 1 November 2026, VAT excluded, standing charge 1,250 won a month — Seoul city price information, city gas rates
- Heat pumps deliver 300–400% of the heat of a gas boiler's 90%, and SCoP and SPF definitions — Energy Saving Trust, heat pumps
- Thermostat range 18–21°C, £120 a year from 22°C to 21°C, £100 a year from programmer, thermostat and TRVs, TRV settings, do not lower flow below 65°C with a cylinder — Energy Saving Trust, using central heating economically (updated 28 October 2026)
- Flow temperature guidance for combi and conventional boilers — Energy Saving Trust, should I turn my boiler's flow temperature down?
- Energy House test results at flow temperatures from 80°C to 50°C, 12% of heating gas from 80°C to 60°C, 17 minutes of warm-up and 0.5°C of room temperature — Nesta, Money Saving Boiler Challenge: supporting evidence
- Annual savings and costs for loft, cavity, solid wall and floor insulation, and draught-proofing — Energy Saving Trust, preparing a home for winter, cavity wall insulation and draught-proofing
Checked 22 November 2026. Heat loss is calculated as Σ(U × area) plus 0.33 Wh per cubic metre per kelvin of ventilation, with 10% added for thermal bridging; monthly energy is the heat-loss coefficient times the temperature difference times 720 hours. Costs use the tariffs above and exclude standing charges. Steady-state arithmetic assumes continuous heating to 20°C and no internal gains, so it runs higher than a metered bill.