At a glance

EPA
Below 60% relative humidity, ideally 30–50%
Korean guidance
40–60%, with 18–22°C; 50% in spring and autumn, 60% in summer, 40% in winter
ASHRAE 55
A ceiling of 0.012 kg/kg humidity ratio — a 16.8°C dew point — and no lower limit at all
A 50-pint dehumidifier
488 W median across 164 certified models; 3.9 kWh a day at eight hours
What that costs
$21 a month at 18.16¢/kWh, about ₩30,000 at Korea's second tier
Electric heating, the same job
1,500 W for five hours is 225 kWh a month; a heat pump does it in 64
Winter airing
Five minutes of cross-draught in a 50 m³ room moves about 55 Wh of heat

Relative humidity is a ratio, not an amount, which is why the same 55% is comfortable in July and damp in January. Warm air holds more water; cool it and the ratio climbs until the water has to go somewhere, usually onto the coldest surface in the room. Every number below — the standards, the wattages, the bills — is a way of managing that one physical fact.

Three authorities, three bands

SourceWhat it saysWhat it is protecting
US EPA, mould guidanceKeep indoor RH below 60%, ideally 30–50%Mould growth on building materials
Korea, indoor air quality guidance40–60% with 18–22°C; 40% in winter, 60% in summerComfort and respiratory health across seasons
ASHRAE Standard 55Humidity ratio at or below 0.012 (16.8°C dew point); no minimum specifiedThermal comfort only

Read the third column and the apparent disagreement dissolves. ASHRAE is a comfort standard and says so: it sets an upper bound on moisture in the air and explicitly declines to set a floor, noting only that very dry air causes skin drying, irritated mucous membranes and static. The EPA is a mould standard, so its ceiling of 60% is the load-bearing number and 30–50 is the comfortable place to sit under it. Korea's 40–60% is a public-health band that changes with the season — 40% in winter because cold outdoor air is dry and overheating a flat drives the ratio down, 60% in summer because air conditioning and heat make the high end tolerable.

A 40–60% target is therefore the intersection of all three, and it is what to hold if you only remember one thing. If you have to pick a single number rather than a band, pick 45–50%: it clears the EPA's ideal range, keeps dust mites suppressed, and stays far enough below the condensation point that the coldest corner of the room does not start running with water.

What happens at each edge

Above 60%, mould becomes a matter of time rather than chance, and dust mites — which absorb water vapour directly from the air — breed fastest above roughly 50%. Below 30%, the discomforts are different: dry eyes and throat, more static, wooden furniture and floorboards shrinking, and airborne droplets travelling further because they evaporate instead of settling. Neither edge is an emergency. Both are cheaper to prevent than to fix, because the mould remediation is the invoice and the humidity meter is the cheap part.

The dew-point test that predicts the wet window

Relative humidity tells you how wet the air is relative to its temperature. Dew point tells you the temperature at which that air gives up its water. The second number is the useful one, because it tells you which surface in the house will be wet before any of them are.

Room at 20°CDew pointWhat condenses
40% RH6.0°COnly single glazing on a hard frost
50% RH9.3°CSingle glazing on an ordinary winter night
60% RH12.0°CSingle glazing most winter nights, plus cold wall corners
65% RH13.5°CWindow reveals, uninsulated wall bases, tile grout

This is the whole argument for holding 45–50% in winter rather than the 55% that feels pleasant. A single-glazed window in a 20°C room sits at 8–12°C on a cold night; at 50% that is borderline, at 60% it is wet by midnight, and the water then runs into the frame and the plaster. The same arithmetic explains the black mould behind furniture: a wall corner at 11°C with 60% air above it is a condenser, whatever the rest of the room reads.

The machines, in watts

MachineTypical drawNote
Dehumidifier, 20–22 pint258 WMedian of 51 certified models
Dehumidifier, 30–32 pint318 WMedian of 21 certified models
Dehumidifier, 50 pint488 WMedian of 164 certified models, 443–490 W
Desiccant dehumidifier, 10 pint340 WWorks below 15°C where a compressor frosts
Air conditioner, dry mode200–600 WCools while it dries; the room gets colder
Ultrasonic humidifier20–40 WCheapest to run, fussiest about water quality
Evaporative humidifier30–60 WSelf-limiting; will not over-humidify
Warm-mist humidifier200–300 WBoils the water; the element costs what it saves in hygiene
Electric resistance heater1,000–1,500 W1 kWh in, 1 kWh of heat out, always
Heat pump (air conditioner in heating mode)300–500 WThree to four times the heat per kWh

A dehumidifier's efficiency is published as an integrated energy factor in litres per kilowatt-hour, and certified compressor models cluster around 2.0 — two litres of water removed per kWh. That number hides something worth knowing: removing one litre of water takes about 0.68 kWh of latent heat out of the air, while the machine only consumes about 0.5 kWh to do it. The difference goes into the room as heat. A dehumidifier warms the room it dries, which is welcome in a cold bedroom in monsoon season and unwelcome in a heatwave, when the air conditioner does the same job while cooling.

The monthly bill, worked out

kWh per month is watts × hours per day × 30 ÷ 1,000. Everything below uses the US residential average of 18.16¢/kWh and Korea's second-tier marginal rate of about ₩258/kWh, which includes the climate and fuel-adjustment charges plus VAT and the industry levy.

Running itkWh / monthUS per monthKorea per month
30-pint, 8 h a day76$13.86₩19,600
50-pint, 8 h a day117$21.27₩30,200
50-pint, 12 h a day176$31.91₩45,300
50-pint, 24 h a day351$63.82₩90,600
Electric heater, 1,500 W, 5 h225$40.86₩58,000
Heat pump, same heat64$11.67₩16,600

Two conclusions. A dehumidifier is not expensive to run if you run it like a tool rather than a background appliance: eight hours a day in the wettest fortnight costs about $21 in the US, and the 24-hour habit costs three times that for very little extra dryness once the room is at target. And heating is where the real money is. An electric resistance heater is the most expensive way to make a room warm, and in Korea it is worse than the table suggests, because 225 kWh on top of a normal month pushes a household from the second tariff tier into the third, where the rate is ₩307.3/kWh rather than ₩214.6.

Compressor, desiccant, or the air conditioner

Compressor dehumidifiers are the normal choice for living space: two litres per kilowatt-hour, and they work best at 20°C and above. Below about 15°C the coil frosts, the machine spends time defrosting, and output collapses — which is exactly when a cold spare room, basement or garage needs one.

Desiccant dehumidifiers use a rotating wheel of silica gel and work at any temperature, down to near freezing. They draw more per litre removed, so they are the right tool for the cold room and the wrong one for the living room.

An air conditioner in dry mode is a dehumidifier that also cools, and in a hot, humid summer it is the most efficient option available because it is moving heat rather than making it. It cannot help in winter, and it will not get a room below about 45% without making it uncomfortably cold.

Ventilation: short and hard beats a window left ajar

Air holds moisture, so replacing indoor air with drier outdoor air is free dehumidification — in winter, when outdoor air is cold and its absolute moisture content is low. The mistake is leaving a window slightly open all day, which loses heat continuously for a small air change. Opening two windows wide for five minutes does the opposite: a large air change for a short time.

The arithmetic is more reassuring than the bills suggest. A 50 m³ room with a cross-draught at roughly two air changes an hour for five minutes moves about 8 m³ of air. Warming that incoming 0°C air to 20°C takes about 55 Wh — around one penny, or ₩15. The same room leaking at 50 m³ an hour all day moves 1,200 m³ and costs about 7.9 kWh a day, which is 238 kWh a month, roughly ₩61,000. Same ventilation, forty times the cost.

Timing follows from the same fact. Airing is most effective when the outdoor air is colder than the indoor air, which means winter mornings and evenings. In the monsoon season the outdoor air is often wetter than the indoor air, so opening windows makes the problem worse and the dehumidifier does the work instead. A CO₂ meter is the practical trigger: above about 1,000 ppm, air the room; below it, the air is fine and the humidity is the only reason to act.

Two routines, winter and monsoon

Winter. Heat to 20–22°C, hold 40–50% RH, and accept that 40% is the sensible floor rather than a compromise. Air the whole flat for five minutes twice a day with a cross-draught. Watch the window frames on the first cold night: water there means the humidity is above 50% or that corner is under-insulated. Run a humidifier only if the meter reads below 35% for days, and prefer an evaporative unit, which cannot over-humidify.

Monsoon. Close the windows when it is raining. Run the air conditioner in dry mode during the day and a compressor dehumidifier in the evening, target 50–55%, and set the dehumidifier on a timer rather than leaving it on. Empty the tank or plumb the drain — a machine that stops at 2 a.m. because the bucket is full has done two hours of work. Check behind furniture against external walls once a week; that is where the first mould appears, and it appears at the humidity you did not measure.

Sources and checks

Checked 18 November 2026. Dew points are calculated with the Magnus formula from the stated room temperature and relative humidity; heat loss uses 0.33 Wh per cubic metre per kelvin. Bills are arithmetic on the published tariffs and exclude standing charges and any tier crossing beyond the one stated.